Supplier

Overview 

Complies with:

  • U.S. FDA FCN 741
  • HPFB (Canada), No Objection
  • EU, No 10/2011

Consult the regulations for complete details.

Additive

Antiblock: No; Slip: No; Processing Aid: No

Resin Properties

Typical Value  (English)
Typical Value  (SI)
Test Method
Density
0.919 g/​cm³
0.919 g/​cm³
ASTM D792
Base Density 
0.919 g/​cm³
0.919 g/​cm³
Dow Method 
Melt Index (190°C/2.16kg)
0.90 g/​10 min 
0.90 g/​10 min 
ASTM D1238

Molded Properties

Film Thickness — Tested 
2 mil
51 μm
Film Puncture Resistance (2.0 mil (51 μm))
201 ft·lb/in³
16.6 J/​cm³ 
Dow Method 
Secant Modulus 
ASTM D882
    2% Secant, MD : 2.0 mil (51 μm)
24400 psi
168 MPa
    2% Secant, TD : 2.0 mil (51 μm)
34500 psi
238 MPa
Tensile Strength 
ASTM D882
    MD : Yield, 2.0 mil (51 μm)
2060 psi
14.2 MPa
    TD : Yield, 2.0 mil (51 μm)
2120 psi
14.6 MPa
    MD : Break, 2.0 mil (51 μm)
7080 psi
48.8 MPa
    TD : Break, 2.0 mil (51 μm)
5680 psi
39.2 MPa
Tensile Elongation 
ASTM D882
    MD : Break, 2.0 mil (51 μm)
620 %
620 %
    TD : Break, 2.0 mil (51 μm)
740 %
740 %
Dart Drop Impact (2.0 mil (51 μm))
300 g
300 g
ASTM D1709A
Elmendorf Tear Strength 
ASTM D1922
    MD : 2.0 mil (51 μm)
720 g
720 g
    TD : 2.0 mil (51 μm)
1000 g
1000 g

Thermal

Vicat Softening Temperature
225 °F
107 °C
ASTM D1525
Melting Temperature (DSC)
248 °F
120 °C
Dow Method 

Optical

Gloss (45°, 2.00 mil (50.8 μm))
63
63
ASTM D2457
Haze (2.00 mil (50.8 μm))
12.0 %
12.0 %
ASTM D1003 

Extrusion Notes

Fabrication Conditions For Blown Film:
  •  Screw Size: 2.5 in. (63.5 mm) 30:1L/D
  •  Screw Type: DSBII
  •  Die Gap: 70 mil (1.8 mm)
  • Output: 10 lb/​hr/​in. of die circumference
  • Die Diameter: 6 in.
  • Blow-Up Ratio: 2.5 : 1

Disclaimer

The information presented here was acquired by Quantum from the producer of the material. Quantum assumes no responsibility or liability for the accuracy of the information contained on this website. Please refer to the downloadable pdf data sheet provided directly by the producer.

Nota:

Esto es una traducción. Quantum no asume responsabilidad alguna por la exactitud de la traducción. Cualquier discrepancia o diferencia creada en la traducción no es vinculante y no tiene ningún efecto legal. Si surge alguna duda relacionada con la exactitud de la información contenida en la ficha técnica traducida, consulte la versión en ingles.

REV: 07/25/2011