Qplast™
QPPLL 2908B
Plastomer Polyethylene
Qplast™ QPPLL 2908B is an ethylene 1‑hexene plastomer, used in monolayer and multilayer film applications. QPPLL 2908B allows for a lower seal initiation temperature relative to its density, high toughness, stiffness, and reduced coefficient of friction on hot metal surfaces.
- Supplier
-
Applications
- Blown Film
- Barrier Food Packaging
- Lamination Film
- Multilayer Packaging Film
Form(s)
Pellets
Resin Properties
Typical Value (English) |
Typical Value (English) |
Test Method |
|
---|---|---|---|
Density | 0.908 g/cm³ |
0.908 g/cm³ | ASTM D792 |
Melt Index (190°C/2.16 kg) | 2.0 g/10 min |
2.0 g/10 min | ASTM D1238 |
Peak Melting Temperature | 237 °F |
114 °C | Proprietary Method |
Film Properties
Tensile Strength at Yield MD | 860 psi |
5.9 MPa | ASTM D882 |
Tensile Strength at Yield TD | 790 psi |
5.4 MPa | ASTM D882 |
Tensile Strength at Break MD | 8600 psi |
60 MPa | ASTM D882 |
Tensile Strength at Break TD | 8200 psi |
60 MPa | ASTM D882 |
Tensile Elongation at Break MD | 480 % |
480 % | ASTM D882 |
Tensile Elongation at Break TD | 570 % |
570 % | ASTM D882 |
Secant Modulus MD — 1% Secant | 12950 psi |
87 MPa | ASTM D882 |
Secant Modulus TD — 1% Secant | 12950 psi |
90 MPa | ASTM D882 |
Dart Drop Impact | 800 g |
800 g | ASTM D1709A |
Elmendorf Tear Strength MD | 210 g |
210 g | ASTM D1922 |
Elmendorf Tear Strength TD | 280 g |
280 g | ASTM D1922 |
Optical Properties
Gloss (45°) | 35 |
35 | ASTM D2457 |
Haze | 18.0 % |
18.0 % | ASTM D1003 |
Disclaimer
The information presented in this document is believed to be accurate as of the date of publication. However, it is provided for general informational purposes only. It does not imply any express or implied warranty or quality specification, including but not limited to warranties of merchantability or fitness for a particular purpose. Users are solely responsible for independently assessing whether the product is suitable for their intended use and ensuring that it can be used safely and in compliance with relevant laws and regulations. We expressly disclaim liability for any loss, damage or injury directly or indirectly suffered or incurred as a result of or related to anyone using or relying on any of the information in this document.
Nota:
Esto es una traducción. Quantum no asume responsabilidad alguna por la exactitud de la traducción. Cualquier discrepancia o diferencia creada en la traducción no es vinculante y no tiene ningún efecto legal. Si surge alguna duda relacionada con la exactitud de la información contenida en la ficha técnica traducida, consulte la versión en ingles.